M 673+A 832
- 1/2inch, Pressure, 20kHz, TEDS
The M 673+A 832 is an IEPE 1/2 inch prepolarized pressure field measurement microphone, which is generally used to measure the acoustic performance of products located in the coupling cavity. The main part is made of stainless steel so that it has good toughness and long time stability.
The M 673+A 832 has a TEDS function, which makes the use of the microphone more convenient and fast. When using multiple microphone arrays, it can be quickly calibrated.
The M 673+A 832 is positioned as a cost-effective microphone designed specifically for audio production line testing of multimedia products. With MegaSig PM 0083 and other IEPE signal conditioner to achieve the best test results.
Description
Specifications
| Parameter | Value |
|---|---|
| TEDS Function | Yes |
| Dimensions | 1/2inch |
| Sound Field Type | Pressure field |
| Polarization Voltage | 0V(Pre-polarized) |
| Frequency Response | 3.15Hz – 20kHz ± 2dB 12.5Hz – 10kHz ± 1dB |
| Dynamic Range | 26dB(A)-147dB(1000 Hz THD <3%) |
| Noise Floor | 26dB(A) |
| Sensitivity mV/Pa (dBV/Pa) | 12.5mV (-38.0dB) ± 2dB |
| IEC 61094-4 Type | WS2P |
| Maximum Output Voltage | 5.6V |
| Output Impedance | <50Ω |
| Supply Power | 2mA - 10mA(Typical4mA) |
| Pressure Equalization Method | Post-equalization |
| Connector Type | BNC |
| Operating Temperature | -30°C to 85°C |
| Temperature Coefficient | -0.012dB/℃ |
| Humidity Coefficient | <0.1dB(0-90% no condensation) |
| Relative Humidity | 0-90% no condensation |
| Static Pressure Coefficient | -0.01dB/kPa |
Dimensions
Overall length | 80.4mm |
Diarmete | 13.2mm |
Diameter (excluding protective grille) | 12.7mm |
Preamplifier mating threads | 11.7mm - 60UNS |

The measuring microphones we produce are precision sensors, and all aspects related to production are strictly controlled, including material selection, production processes, testing control, and production environment.
|
![]() We adopt advanced production processes and fully automated precision machining equipment, which significantly reduces the accuracy errors caused by secondary clamping in traditional machining equipment. This greatly enhances the dimensional consistency, geometric accuracy, and overall quality stability of the products, providing reliable technical support for demanding application scenarios. |
![]() At the same time, we employ extremely rigorous testing and control measures, conducting quantitative testing on any links that may lead to product quality issues, and implementing test sequence control to prevent skip-station situations. The comprehensive MES control enables all data to be traceable, ensuring a high degree of consistency in sensor quality. |
The entire production process of all our microphones is strictly carried out in a dust-free workshop, which can minimize the amount of dust in the air, thus creating a stable and pure working environment for the sensors. This ensures a long and stable lifespan for the sensors and maintains their excellent performance throughout daily use. |