SS 601&603
- Semi-permanent outdoor microphone kit
SS 601/603 is a special microphone kit for outdoor monitoring, which can prevent wind noise, rain, and birds from roost, etc., and is suitable for use in outdoor regular weather. The bird cone can be easily removed for daily maintenance calibration. The shell is made of aluminum alloy and surface treatment, which is resistant to environmental corrosion and ensures the long-term stability of the microphone.
SS 601/603 meets IP55 protection grade, 50mm diameter wind hood and internal rain cover, dust screen, can fully protect the microphone, can withstand the test of wind, rain, snow and other bad weather, and prevent dust damage to the microphone. The SS 601/603 is optimized for 90° incidence and mainly for urban, traffic and industrial noise measurements.
Description
Specifications
| Parameter | Value |
|---|---|
| TEDS Function | No |
| Dimensions | 1/2inch |
| Sound Field Type | SS 601:Free field Ⅱtype SS 603:Free field Ⅰtype |
| Polarization Voltage | / |
| Frequency Response | SS 601: 3.15Hz – 16kHz ± 2dB 12.5Hz – 10kHz ± 1dB S 603: 3.15Hz – 20kHz ± 2dB 12.5Hz – 10kHz ± 1dB |
| Dynamic Range | 17dB(A)-135dB (1000 Hz 失真<3%) |
| Noise Floor | 17dB(A) |
| Sensitivity mV/Pa (dBV/Pa) | 50mV (-26.0dB) ± 2dB |
| IEC 61094-4 Type | WS2F |
| Maximum Output Voltage | 5.6V |
| Output Impedance | <50Ω |
| Supply Power | 2mA-20mA(Typical 4mA) |
| Pressure Equalization Method | Post-equalization |
| Connector Type | BNC |
| Operating Temperature | -30°C to 80°C |
| Temperature Coefficient | / |
| Humidity Coefficient | <0.1dB(10%- 90% no condensation) |
| Relative Humidity | 10%- 90% no condensation |
| Static Pressure Coefficient | / |
Specifications
Types of Acoustic Fields | Free Field |
Polarization voltages | 0V(Prepolarized) |
Frequency range | SS 601:3.15Hz – 16kHz ± 2dB 12.5Hz – 10kHz ± 1dB SS 603:3.15Hz – 20kHz ± 2dB 12.5Hz – 10kHz ± 1dB |
Dynamic range | 17dB(A)-135dB(1000 Hz THD<3%) |
Background noise | 17dB(A) |
Sensitivity mV/Pa(dBV/Pa) | 50mV (-26.0dB) ± 2dB |
Maximum Output Voltage | 5.6V |
Output Impedance | <50Ω |
Pwer Supply | 2mA - 20mA(typical 4mA) |
Pressure Equalization Method | Post-equalization |
Connection | BNC |
Temperature range, operation | -20℃ to 60℃ |
Temperature range, storage | Temperature:25℃±5℃,Humidity:50%±15%RH(Ensure the long-term stability of the sensor) |
| Humidity range non condensing | 10 - 90% without condensation |
Humidity coefficient | <0.1dB |
Dimensions
Overall length | 278mm |
Diarmete | Ø25mm |
Gripping part dimensions | Ø23*33mm |
The measuring microphones we produce are precision sensors, and all aspects related to production are strictly controlled, including material selection, production processes, testing control, and production environment.
|
![]() We adopt advanced production processes and fully automated precision machining equipment, which significantly reduces the accuracy errors caused by secondary clamping in traditional machining equipment. This greatly enhances the dimensional consistency, geometric accuracy, and overall quality stability of the products, providing reliable technical support for demanding application scenarios. |
![]() At the same time, we employ extremely rigorous testing and control measures, conducting quantitative testing on any links that may lead to product quality issues, and implementing test sequence control to prevent skip-station situations. The comprehensive MES control enables all data to be traceable, ensuring a high degree of consistency in sensor quality. |
The entire production process of all our microphones is strictly carried out in a dust-free workshop, which can minimize the amount of dust in the air, thus creating a stable and pure working environment for the sensors. This ensures a long and stable lifespan for the sensors and maintains their excellent performance throughout daily use. |