HomeProductsSensorsMicrophone kitSpecial microphone kit with TEDS for harsh working conditions
Special microphone kit with TEDS for harsh working conditions

SS 605

  • Special microphone kit with TEDS for harsh working conditions
  • SS 605 is an IEPE type 1/2-inch pre polarized free field measurement microphone used to measure the undistorted true sound pressure before the microphone is placed in the sound field.

    SS 605 is specially designed with an integrated microphone and preamplifier that cannot be disassembled. It is oil, water, and dust resistant, and can be used normally in harsh environments such as high and low temperatures, water, oil mist, and dust. The protection level can reach IP65, and it supports TEDS. It is commonly used for testing NVH, engines, motors, etc.



  • Description
  • Download

Description

Specifications


ParameterValue
TEDS FunctionYes
Dimensions1/2inch
Sound Field TypeFree field
Polarization Voltage0V(Pre-polarized)
Frequency Response3.15Hz – 20kHz ± 2dB 12.5Hz – 10kHz ± 1dB
Dynamic Range17dB(A)-135dB(1000 Hz 失真<3%)
Noise Floor17dB(A)
Sensitivity mV/Pa (dBV/Pa)50mV/Pa -26.0dB ± 2dB
IEC 61094-4 TypeWS2F
Maximum Output Voltage5.6V
Output Impedance<50Ω
Supply Power2mA - 20mA(Typical4mA)
Pressure Equalization MethodPost-equalization
Connector TypeBNC
Operating Temperature-50°C to 95°C
Temperature Coefficient-0.001dB/℃
Humidity Coefficient<0.1dB(0%- 90% no condensation)
Relative Humidity0%- 90% no condensation
Static Pressure Coefficient-0.01dB/kPa

Specifications


Specifications

Types of Acoustic Fields

Free Field

Polarization voltages

0V(Prepolarized)

Frequency range

3.15Hz – 20kHz ± 2dB  12.5Hz – 10kHz ± 1dB

Dynamic range

17dB(A)-135dB(1000 Hz  THD<3%)

Background noise

17dB(A)

Sensitivity  mV/Pa(dBV/Pa)

(50±10)mV (-26.0dB± 2dB) re 1V/Pa

TEDS function

2mA - 20mA(typical 4mA)

Length

Post-equalization

Interface

BNC
Temperature range-50℃ - 95℃
Temperature range coefficient-0.001dB/℃
RH0% - 90% non condensation
Relative humidity coefficient<0.1dB (0% - 90% non condensation)

Static pressure coefficient

-0.011dB/kPa

Storage condition

Temperature: 25 ℃± 5 ℃, humidity: 50% ± 15% RH (ensuring long-term stability of the sensor)

TEDS

Support

TEDS


TypeSupported information fields
Basic InformationSerial Number 

Frequency response


SS 605曲线.png

Dimensions mm




Dimension parameters
Overall length (Including interfaces)85.6mm
Length ( Excluding interfaces ) 74.6mm
Diameter (with protective grid) 14.6mm
Diameter (without protective grid)12.7mm

137.png

Ordering Information


PNModelDescription
910024-01PM 0083Power amplifier
900002-39 SS 605TEDS microphone kit for harsh conditions
730003-000103A50Ω BNC _BNC low-noise cable,customizable length
730003-030103A03050Ω BNC _BNC low-noise cable,length 3.0m
730003-060103A06050Ω BNC _BNC low-noise cablelength 6.0m
730003-090103A09050Ω BNC _BNC low-noise cablelength 9.0m

The measuring microphones we produce are precision sensors, and all aspects related to production are strictly controlled, including material selection, production processes, testing control, and production environment.

图片1.pngAfter years of continuous improvement, we now use special nickel alloy materials as the core material for the diaphragm. Compared to other alloy materials, it exhibits higher sensitivity, lower distortion rate, and more stable long-term performance. The front body of the microphone is made of stainless steel, ensuring that the entire microphone maintains extremely robust structural characteristics even under various assembly conditions.

图片2.png

We adopt advanced production processes and fully automated precision machining equipment, which significantly reduces the accuracy errors caused by secondary clamping in traditional machining equipment. This greatly enhances the dimensional consistency, geometric accuracy, and overall quality stability of the products, providing reliable technical support for demanding application scenarios.

图片3.png

At the same time, we employ extremely rigorous testing and control measures, conducting quantitative testing on any links that may lead to product quality issues, and implementing test sequence control to prevent skip-station situations. The comprehensive MES control enables all data to be traceable, ensuring a high degree of consistency in sensor quality.

图片4.pngThe entire production process of all our microphones is strictly carried out in a dust-free workshop, which can minimize the amount of dust in the air, thus creating a stable and pure working environment for the sensors. This ensures a long and stable lifespan for the sensors and maintains their excellent performance throughout daily use.