AH 268
- Dual axis dynamic acoustic simulation testing system
The AH 268 dual axis dynamic acoustic simulation testing system inherits the core functions of the AH 265 high-precision simulated human head model and innovatively integrates a dual axis rotation system and a human-machine interaction control module. It supports controlling the model's horizontal ± 90 ° and vertical ± 90 ° dynamic deflection through a touch interface, or receiving external program instructions to achieve automated testing, breaking through the limitations of traditional static simulation.
Description
Specifications
Artificial ear | |
Pressure-field microphone frequency response | 20Hz - 8kHz ± 0.5dB 8kHz - 16kHz ± 1dB |
Noise floor | <16dB(A) |
Sensitivity | 50mV/Pa (-26.0dB)±2dB |
| Dynamic range | 16dB(A)-135dB(A) |
| Working voltage | IEPE,4mA |
Basic characteristics: 1. Simulate the anatomical shape of the auricle with reference to ITU-T P.57, type 3.3 auricle 2. Complies with IEC 60318-4:2010 Ed.1.0 (formerly IEC 60711) electroacoustics - Simulators for the human ear and head, Part 4: Blocked ear simulators for measuring insertion earphones 3. Compliant with ITU-T Recommendation P.57 (08/96) P-series: Telephone Transmission Quality, Measurement Target Equipment: Simulated Ear 4. Compliant with SJ/T 10659-1995 Measurement Plug in Ear Simulator for Plug in Earphones | |
Artificial mouth | |
Range | 100Hz - 10kHz |
Maximum power | 10W |
Impedance | 4ohm |
| Frequency response (after equalization)) | Satisfy ETSI TS 102 924 |
| THD | Superior to ITU-T P.58 standard |
| Basic characteristics: 1. Comply with the requirements of IEEE269661 international standard and ITU-T P.51 recommendation for transmitting acoustic signals at the "mouth reference point" 2. Acoustic measurement standard sound source 3. Low distortion, high stability | |
Use&Place environment | |
Temperature range for use | 0 - 50 °C, 32°F - 122°F |
Storage Temperature Range | -20 - 70°C, -4°F - 158°F |
Humidity | 20 - 80% RH |
Head and torso | |
Dimensions | 400*200*680mm |
| Weight | About 23Kg |
| Horizontal/Vertical deflection angle | ±90° |
| Deflection accuracy | ±0.1 |
| Maximum horizontal rotational speed | 20rpm |
| Maximum vertical rotational speed | 10rpm |
| Configure: 1. The external geometric dimensions must comply with ITU-T P.58 2. Consistency of headphone placement and retrieval 3. Meet the testing needs of various scenarios such as headphones, smart glasses, and car intelligent cockpits | |
Dual axis dynamic acoustic simulation testing system AH 268 frequency response curve