HomeProductsSensorsSimulator HeadDual axis dynamic acoustic simulation testing system
Dual axis dynamic acoustic simulation testing system

AH 268

  • Dual axis dynamic acoustic simulation testing system
  • The AH 268 dual axis dynamic acoustic simulation testing system inherits the core functions of the AH 265 high-precision simulated human head model and innovatively integrates a dual axis rotation system and a human-machine interaction control module. It supports controlling the model's horizontal ± 90 ° and vertical ± 90 ° dynamic deflection through a touch interface, or receiving external program instructions to achieve automated testing, breaking through the limitations of traditional static simulation. 

  • Description
  • Download

Description


Specifications


Artificial ear

Pressure-field microphone frequency response

20Hz - 8kHz ± 0.5dB   8kHz - 16kHz ± 1dB

Noise floor

<16dB(A)

Sensitivity 

50mV/Pa (-26.0dB)±2dB

Dynamic range 

16dB(A)-135dB(A)

Working voltage

IEPE,4mA

Basic characteristics:

1. Simulate the anatomical shape of the auricle with reference to ITU-T P.57, type 3.3 auricle

2. Complies with IEC 60318-4:2010 Ed.1.0 (formerly IEC 60711) electroacoustics - Simulators for the human ear and head, Part 4: Blocked ear simulators for measuring insertion earphones

3. Compliant with ITU-T Recommendation P.57 (08/96) P-series: Telephone Transmission Quality, Measurement Target Equipment: Simulated Ear

4. Compliant with SJ/T 10659-1995 Measurement Plug in Ear Simulator for Plug in Earphones


Artificial mouth

Range

100Hz - 10kHz

Maximum power

10W

Impedance

4ohm

Frequency response

 (after equalization)) 

Satisfy ETSI TS 102 924

THD

Superior to ITU-T P.58 standard

Basic characteristics:

1. Comply with the requirements of IEEE269661 international standard and ITU-T P.51 recommendation for transmitting acoustic signals at the "mouth reference point"

2. Acoustic measurement standard sound source

3. Low distortion, high stability


Use&Place environment

Temperature range for use

0 -  50 °C, 32°F - 122°F

Storage Temperature Range

-20 - 70°C, -4°F - 158°F

Humidity

20 - 80% RH

Head and torso

Dimensions

400*200*680mm

Weight

About 23Kg

Horizontal/Vertical deflection angle±90°
Deflection accuracy±0.1
Maximum horizontal rotational speed20rpm
Maximum vertical rotational speed10rpm
Configure:

1. The external geometric dimensions must comply with ITU-T P.58

2. Consistency of headphone placement and retrieval

3. Meet the testing needs of various scenarios such as headphones, smart glasses, and car intelligent cockpits



Dual axis dynamic acoustic simulation testing system AH 268 frequency response curve


28.png

28-5.png

28-2.png